INCINERATOR

CONTROLLING ENVIRONMENT SAFETY TOWARDS PURITY

BURNING SOLUTION FOR MEDICAL & BIO-MEDICAL WASTE



Everything under control
....Whenever and wherever
necessary.

EMISSION TREATMENT FACILITIES

Special Features:

Solid Waste generate in various type of Animal and Human waste, treatment rooms and laboratories arising out of cotton wastes, bandages, floor sweeping waste, basket etc. besides containing decomposable organic materials and varying amount of water also contain a vide variety of pathogenic micro organism. One of the best method of disposing of such waste for the purpose of pollution free environment is to burn the waste materials cleanly. To prevent secondary generation of toxic pollution, it becomes essential to eliminate certain potential hazardous waste and installation of proper air pollution control system. Consequently, proper design, operation and maintenance of  MEDIWASTE incinerators become an essential part of the systems.

  • Secondary Chamber : The Secondary Chamber in mainly incorporated with the system for re-burning of emission. The chamber gas residence time shall be at least one second at 1050oC +/-50oC.

  • Dilution : A fresh air incorporated with the system for dilute of flue gases through a powerful blower.

  • Gravity Settling Chamber : The gravity settling chamber is dust & solid collection equipment. Consisting of a chamber in which the gas velocity is reduced to enable dust & solid to settle out by the action of gravity. It is specially design a cylindrical or conical chamber. 

  • Wet Scrubber : The wet scrubber unit is specially designed to removal of dispersed from gases. In the conventional air washer the gas is passed through banks of sprays which may be directed downward, Upward, into the gas stream, or with the gas stream. Consisting of the banks of nozzles & water circulation pump. A set of zigzag eliminator is provided.
  • Dry scrubber : The dry scrubber is designed for absorption of foul odor. When gases or air are moved through the system, the gases or air will be purified.
  • Ducting & I.D. Fan : The Ducting arrangements for flue gases complete with require dampers assembly and I.D. Fan will be provided.
  • Chimney : One heavy duty chimney having 30 meter high from ground level to be incorporated along with the system completed with sampling port, platform & ladder, lighting arrester, Bird Cage, Aviation Light.
MODEL MT-50 (Mini) MT-51 (Mini) MT-52 MT-53 MT-54 MT-55 MT-56 MT-57

Capacity per Hour

2.5 Kg. 5 Kg. 10 Kg. 20 Kg. 50 Kg. 100 Kg. 150 Kg. 200 Kg.

Temperature
(Incinerator)

850oC
+/- 50oC

850oC
+/- 50oC

850oC
+/- 50oC

850oC
+/- 50oC

850oC
+/- 50oC

850oC
+/- 50oC

850oC
+/- 50oC

850oC
+/- 50oC

Temperature
(Secondary Chamber)

1050oC
+/- 50oC
1050oC
+/- 50oC
1050oC
+/- 50oC
1050oC
+/- 50oC
1050oC
+/- 50oC
1050oC
+/- 50oC
1050oC
+/- 50oC
1050oC
+/- 50oC

Power Supply A.C. Main

440 Volt
3 Phase
4 Wire
440 Volt
3 Phase
4 Wire
440 Volt
3 Phase
4 Wire
440 Volt
3 Phase
4 Wire
440 Volt
3 Phase
4 Wire
440 Volt
3 Phase
4 Wire
440 Volt
3 Phase
4 Wire
440 Volt
3 Phase
4 Wire

Rating

3 KW per Phase 5 KW per Phase 7 KW per Phase 9 KW per Phase 18 KW per Phase 30 KW per Phase 45 KW per Phase 60 KW per Phase

Chimney (Stack Height AboveGround)

2 Meter 2 Meter 2 Meter 5 Meter 30 Meter 30 Meter 30 Meter 30 Meter

Space Req.
Approximate
W X H X L

3'x6'x6' 3'x6'x6' 8'x8'x10' 10'x10'x15' 10'x10'x15' 10'x15'x15' 10'x15'x20' 15'x20'x20'

 Any specific & larger sizes of Incinerator plant can be manufactured as per customers requirement

 

Other Range of Products

* MEDICAL COLLEGE & HOSPITALS
* NURSING HOMES
* CLINICS
* PHARMACEUTICALS
* FOOD PROCESSING
* LABORATORIES
* SLOTTING HOUSES
* HATCHERIES
* HOTELS
* INDUSTRIALS

TEMPERATURE CALIBRATOR
INDUSTRIAL FURNACE
INDUSTRIAL OVEN
CORROSION RESISTANT EQUIPMENT 
CHEMICAL PLANT
LABORATORY APPLIANCES
CONTROL PANEL


Site : www.cypo.com
Email : mictrothermal@cypo.com

Sign up for PayPal and start accepting credit card payments instantly.